Magnaflux Zyglo® ZL-27A Level 3 Post Emulsifiable Fluorescent Penetrant
Magnaflux
Designed to remove excess surface penetrant, ZR-10E minimizes surface background during Method D fluorescent penetrant testing while protecting indication integrity in critical component inspections. ZR-10E provides long tank life and excellent solution consistency for dependable, long-lasting performance in a variety of applications.
This Method D remover reduces fluorescent background on rough surfaces and minimizes penetrant bleed-out from hollow parts.
ZR-10E is tested and approved to AMS 2644 to work with Magnaflux PE penetrants ZL-2C Level 2, ZL-27A Level 3 and ZL-37 Level 4 for verified penetrant system reliability.
ZR-10E is listed on the QPL SAE AMS 2644 Qualified Product List and is approved for use by Pratt & Whitney.
Ideal application: Castings, Detecting fine to very-fine discontinuities, High-stress parts, Investment castings, Precision components, Safety-critical components, Turbine engine blades, disks, etc.
Defect examples: Cracks, Porosity, Scratches, Seams
AECL, AMS 2644, AMS 2647, ASME BPVC, ASTM E1417, ASTM E165, Boeing BAC 5423 PSD 6-46 or 8-4, Boeing PS-21202, GE P3TF2, GE P50YP107, Honeywell EMS 52309, MIL-STD-2132, MIL-STD-271, NAVSEA T9074-AS-GIB-010/271, Pratt & Whitney 4355
Product description, properties and specification compliance as published by Magnaflux on the ZR-10E product page and Product Data Sheet (rev. July 2020).
| NDT Type | Fluorescent Penetrant Testing, Visible Penetrant Testing |
|---|---|
| Penetrant Type | Type 1, Type 2 |
| Penetrant Method | Method D |