200 NTU for Hach 2100N/AN Instruments, Amco Clear Turbidity Standard
GFS

200 NTU for Hach 2100N/AN Instruments, Amco Clear Turbidity Standard

AMCO Clear Turbidity Standards

AMCO Clear Turbidity Standards are EPA-approved primary standards designed to deliver consistent, reliable calibration for turbidity meters, without the hazards and challenges of formazin polymer standards. Produced as a stable aqueous polymer (SDVB) suspension, these standards never settle, never require mixing, and offer unmatched ease of use. Each lot is NIST traceable, normalized to historical lots, and verified for photometric accuracy using UV-VIS spectroscopy, ensuring confidence in every measurement.

Benefits of AMCO Clear: Ready-to-Use Convenience
  • Prediluted and stable — no daily preparation or inversion, and no remixing required
  • A true suspension for consistent, repeatable performance
Safer for Users and the Environment
  • Non-toxic, non-carcinogenic formulation
  • Easy, environmentally friendly disposal
Save Time and Reduce Labor
  • Eliminates the labor-intensive preparation required for formazin
  • No settling or degradation — standards maintain accuracy and reduce uncertainty
  • More stable than any formazin preparation
Confidence in Every Result
  • Lot-to-lot accuracy within ±1%
  • NIST traceable thanks to consistent particle size and UV-VIS verified photometric performance
  • Formulated to ISO 17034 4000 NTU formazin dilutions
Compliance
  • EPA Method 180.1 and ISO 7027-1:2016 approved
  • Produced in an ISO 17025 accredited laboratory


Instrument Compatibility
Instrument Make: Hach
Instrument Model: 2100N IS/AN IS (TL2310/2360), 2100N/AN (TL2300/2350)

Specifications
Turbidity Value: 200 NTU
Contents: 250 ML bottle
For Use With (Instrument): Hach 2100N/AN (TL2300/2350); Hach 2100N IS/AN IS (TL2310/2360)
Storage: Store at room temperature. Do not freeze or store in extreme heat.
Use and Handling: Ready‑to‑use standards - no dilution or mixing required. Avoid shaking, as air bubbles may affect measurement accuracy. For primary standards, pour the needed amount into a clean sample container and run per instrument manufacturer's instructions. For secondary standards, place the vial directly into the instrument and operate per instrument manufacturer's instructions. Dispose of used material as nonhazardous waste and do not return any product to the original container to prevent contamination.
NTU/FNU:
200 NTU
Item No: 85249
$109.27
( 250 ML )
Current Stock:

LEAD TIME

5 - 7 Days